A block inspection is only as good as the record it leaves behind. Most of the trouble comes from the areas that get checked differently each time, or not written down at all.
Walking a block is not hard. Walking twenty blocks a month, in the same order, recording the same things, with photographs that can be found a year later, is where the job actually lives. The inspection that gets challenged is rarely the one where something obvious was missed. It is the one where nobody can show what the stairwell looked like at the last visit, or prove the fire door on the second floor was closing properly when it was checked.
This checklist follows the order most managing agents walk a building: outside first, then in through the entrance, up through the common parts, and down to the plant room. Use it as it is, or as the starting point for your own template.
Before you go
Ten minutes at the desk saves the visit from turning into a reconstruction afterwards.
Pull the last inspection report so you can compare item by item, not from memory.
Check the open actions from last time: repairs raised, contractor visits booked, anything promised to a leaseholder.
Read the current fire risk assessment action plan, so you know which measures the assessor is relying on.
Know where the asbestos register says known materials are in the common parts, so you can look at their condition.
Confirm access: keys and fobs for the plant room, roof hatch, bin store and riser cupboards.
If flat entrance door checks are due, confirm which residents have agreed a time.
Outside and the approach
Paths, steps and ramps: trip hazards, loose paving, handrails secure.
External lighting working, including any on a timer or sensor.
Boundary walls, fences and gates: damage, and gates that close and latch.
Fire assembly point signage, where the building has one.
Fire service access clear: nothing parked or stored across it.
Visible condition of the external walls, gutters and downpipes from ground level.
Entrance and door entry
Main entrance door closes and locks on its own.
Door entry system and fob reader working.
Fire action notice displayed and legible.
Post area tidy, with no build-up of leaflets or parcels in the escape route.
Notice board current, with out of date notices removed.
Hallways, landings and stairs
This is the escape route, so treat anything in it as a fire safety issue first and a tidiness issue second.
Escape routes clear: no bikes, prams, furniture, mobility scooters or rubbish.
Nothing combustible stored in the stair or under it.
Flooring secure, with no lifted carpet, loose nosings or trip hazards.
Handrails and balustrades secure.
Walls and ceilings: new damage, damp, staining or cracks, with a note of whether each is new since last time.
Lighting working on every landing.
Emergency lighting units present and showing a healthy indicator where they have one.
Smoke vents and automatic opening vents clear and not obstructed.
Fire alarm call points and detectors undamaged, where the building has a communal system.
Fire extinguishers in place and in date, where provided.
Fire doors
Fire doors are the one part of a block inspection with specific legal requirements in England, so they deserve their own section in the template rather than a single tick box.
Under the Fire Safety (England) Regulations 2022, the responsible person for a block with two or more flats must give residents information about fire doors: keep them shut, do not tamper with self-closers, report faults. Where the top storey is above 11 metres, the responsible person must also check fire doors in the communal areas at least every three months, and use best endeavours to check flat entrance doors at least every twelve months. A record has to be kept of the steps taken, including any flat where access was not granted.
Who can do the checks. Government guidance is clear that these are visual checks, with no tools and no specialist needed. With simple instruction, managing agents, caretakers and maintenance staff can do them, including during other routine visits. The guidance also notes you can plan and record the checks electronically.
For every communal fire door
Open the door fully and let it go. It should close fully into its frame, overcoming any latch.
Open it to around 15 degrees and let it go. It should still close fully.
Self-closing device present, attached and not disconnected.
Door not wedged, propped or held open, unless on an approved hold-open device.
Door leaf, frame and any glazing undamaged, and glazing not obviously replaced.
Intumescent strips and smoke seals present and undamaged, where fitted.
Hinges secure, with no missing screws.
"Fire door keep shut" signage in place where required.
Riser, electrical and storage cupboard doors kept locked shut.
For flat entrance doors
The same closing test: from fully open and from around 15 degrees.
Door, frame and glazing undamaged, and any seals intact.
No obvious alterations, such as a replaced door, removed closer or added cat flap.
Where access is not granted: the date, how the resident was contacted, and what they said.
Defects should be put right as soon as reasonably practicable, depending on the risk. Record what was found and who was told on the same report as the check, so the follow-up sits with the evidence.
Lifts
Lift working, levelling properly at each floor, and doors opening and closing cleanly.
Emergency alarm or phone in the car working.
Car interior: lighting, panels, flooring and any damage.
Report of the most recent thorough examination available. Under LOLER, passenger lifts need one at least every six months.
Bin stores, cycle stores and car parks
Bins not overflowing, and no fly-tipping or bulky items left.
Bin store doors close and lock, and the store is not being used for storage.
Signs of pests.
Cycle store secure and not overspilling into the building.
Car park lighting, barriers and markings, and any abandoned vehicles.
Gardens and grounds
Grounds maintenance carried out to the contract.
Trees and hedges: overhanging branches, or roots lifting paths.
Play equipment and seating, where provided, safe and undamaged.
Plant rooms, risers and service areas
Usually the room with no signal, the least foot traffic and the most that can go wrong without anyone noticing. Look, record and photograph. Do not touch plant you are not trained on.
Door locked, and signage in place.
Room clear, with nothing stored that should not be there.
Signs of leaks, water on the floor, or staining below pipework.
Plant running without unusual noise, and any warning lights or fault indicators noted.
Water system checks recorded as your Legionella risk assessment sets out.
Electrical intake and meter cupboards locked, clear and undamaged.
Condition of any known asbestos-containing materials listed in the register.
Service records and logbooks on site, where kept there.
Roof access
Only where it is safe and you are authorised. In most cases this is a check from the hatch or a safe vantage point, not a walk across the roof.
Roof hatch or door secure and locked.
Visible debris, blocked outlets or damaged coverings.
Taller buildings carry more
In England, residential blocks above 18 metres carry further duties under the same fire safety regulations, including a secure information box for the fire service, floor and flat identification signage, and regular checks of lifts for firefighters and other firefighting equipment. Higher-risk buildings also have duties under the Building Safety Act 2022. If you manage buildings in that category, the checklist above is the floor, not the ceiling, and your template should follow the duties set out for that building.
Recording it so it holds up
The checklist tells you what to look at. How you record it decides whether the report is any use when it is needed.
The same areas, in the same order, every time. Two reports that list the building differently cannot be compared.
Photographs against the item. A photo of a damaged fire door seal sitting against "Second floor, cross-corridor door, smoke seal" proves something. The same photo in a gallery of eighty proves very little.
Describe, do not judge. "Stair carpet lifted at third step, 200mm, trip hazard" is evidence. "Stairs in poor condition" is an opinion.
New or existing. Say whether each defect was there at the last visit. That one word answers most contractor disputes.
The action, on the same record. Who was told, when, and what was instructed. A defect recorded with no action trail shows that you knew. A defect with the action shows that you acted.
Dated at the time, by a named person. Not typed up two days later from notes.
Each check is dated, attributed and carries its own photo.
Frequently asked
How often should communal areas be inspected?
There is no single statutory frequency for a general communal inspection. It is usually set by the management agreement and the fire risk assessment. Fire doors are the exception in England: in blocks with a top storey above 11 metres, communal fire doors must be checked at least every three months, and flat entrance doors, on a best endeavours basis, at least every twelve months.
Who can carry out fire door checks?
Government guidance says the checks are visual and do not need a specialist. With simple instruction, managing agents, caretakers, housing officers and maintenance staff can carry them out, including during other routine visits.
What should a fire door check include?
At minimum, that the self-closer works and the door closes fully into its frame from fully open and from about 15 degrees. Also check the door, frame and glazing are undamaged, intumescent strips and smoke seals are intact where fitted, and riser and cupboard doors are kept locked shut.
What if a leaseholder refuses access?
Record it. The regulations require a record of the steps taken to check flat entrance doors, including how you tried to gain access where it was not granted. Note each attempt, how the resident was contacted and the response.
Is a block inspection the same as a fire risk assessment?
No. A fire risk assessment is a formal assessment by a competent person under the Regulatory Reform (Fire Safety) Order 2005. A routine inspection records the condition of the common parts and checks that the measures the assessment relies on are still in place.
Turn the checklist into a template
A checklist on paper still has to be typed up, photographed, matched and filed. Built as a template in TouchRight, the same list runs on a phone or tablet in the order you walk the building, works with no signal in the plant room, attaches each photograph to the item it shows, and lets you tag a defect and push it to Fixflo or a contractor before you leave.